Fragen for tag „OCPP Cfos Charging Manager“ (1)

Stimmen
Antworten
Ansichten
Fragen
0
Stimmen
9
antworten
68
Aufrufe
vor 1 Monat gefragt von
aktualisiert vor 3 Wochen von
Hi all, I have a Shelly 3EM measuring the total house input power on a 3 phase installation (3x40A) and a Vestel EVC04 charger limitted to 32A (i.e. 22kw mode) attached in OCPP mode which the Cfos Charging Manager in load balancing mode.  The Total h...
14. November 2022
Finally I have a working setup. Tried MODBUS TCP connection of CFos CM to the EVC04 Wallbox. It works. Thanks. Needed to start MODBUS TCP server in the EVC04 configuration by enabling Local Last Management:MODBUS TCP. Then it started MODBUS TCP standard port 502/Device ID 255. Of course the Wallbox needs to be connected either ...mehr lesen



Schreibe einen Kommentar